Condensate safety overflow switch

DiversiTech offers three different switches to help keep condensate overflow under control. The AA2-FS is an emergency condensate overflow switch for both the primary and auxiliary pans. I was taught to break the yellow wire as well for the compressor on safety switches in trade school. With the new regs, I am breaking red or the volt . With models to fit most types of installations and code requirements, these .

No overflow , means no water damage to your ceiling or .

Condensate Overflow Safety Switch.

Snaps easily over existing drain line tubing and can be glued in place using PVC cement. The SOS electronically senses water near the inside wall of the PVC drain tubing. By locating the SOS with its body away from the normal flow, . Designed to detect downstream clogs or blockages in air conditioning equipment condensate drains and will shut off equipment to prevent flooding. Easily installs in auxiliary pan drain outlet or air conditioning equipment safety overflow outlet.


Reliable mechanical switch and solid . This versatile plenum rated trap. Disclaimer: All power must be shut off before repairs are made. Fix My Own AC accepts no responsibility for . While doing this, I added an LED to help troubleshoot the HVAC. If the drain plugs again, or the switch fails open and shuts off the system, the red LED will illuminate to help me quickly find the problem. You should place tape or heat . Video Guide to using condensate traps and overflow switches for your air handler.


Featured is the Easy Trap model EZT-21 one of the. ACS-is designed to detect downstream clogs or blockages in air conditioning equipment condensate drain lines and either shut down the equipment, thus stopping the production of condensate or alert users to the potential over flow condition. ACS-installs directly to the primary drain pan outlet or in-line on the. Installs vertically or horizontally in primary drain or can be plugged on auxilliary pans.


Pre-wired with 4-foot, AWG wires. I installed this in the attic ceiling HVAC safety pan and also overflow cutoff switches in the main and secondary condensate drain lines. Discovered my condensate pump stopped working (worn float) and overflowed for probably most of the week.


Problem is the shut off does not . Quickly clears slime, mold and dirt plugs out of primary and secondary drain lines. Inline, low voltage condensate overflow shutoff switch.