Secondly, they need to insert the boiler live wire on one side of the terminal block and the pump safety wire on the other side. The correct wiring scheme for shutting down the AC completely is to break the 24v red wire (low voltage) coming from the t-stat bundle and then wire it in to the ( COM) terminal of the pump. Then attach the second lead to the (RUN) terminal at the pump to the second red wire going to the control . I have a Little Giant condensate pump VCMX-model. This pump comes with a safety switch .
The pump turns on when the water level gets to 1.
The safety switch will do something when the water level reaches 2.
Do those pump safety switches typically work in dead-man fashion, so that the switch opens if power is interrupted to the pump ? Disclaimer: All power must be shut off before repairs are made. Fix My Own AC accepts no responsibility for . How to install and connect AC float switch , Rectarseal SS2. Condensate pump operation explained and troubleshooting common condensate pump problems. I have an issue where the pump works and will switch on and pump the water out once the float trips the switch , but it will continue to run after the water is pumped out, the basin is empty and the float has . Two sets of wires leave the pump. The high-voltage wires power the float switch and pump . Furnace guy just left here yesterday after brand new furnace install.
Did not connect condensate pump safety switch up along with the cardboard is still on the pump. In this HVAC Installation Training Video, I go over the basics of the HVAC Condensate Trap, Low Voltage Wiring, Emergency Condensate Pan, Float Switch Mounti. The safety switch comes from the factory with leads connected to the COM and NO switch terminals. If fused plug is used on 230V units, a 1. Run flexible tubing or pipe from evaporator drain into one of the three pump inlets . Also includes instructions for wiring normally open switch systems (for the CP-or other condensate pumps ). Name, VCMA-15UL 115-Volt Automatic Condensate Removal Pump , VCMA- 15ULS 115-Volt Condensate Removal Pump with Safety Switch , VCMA-20ULS 115-Volt Condensate Removal Pump , VCMA-20ULST 115-Volt Condensate Removal Pump.
Bran Little Giant, Little Giant, Little Giant, Little Giant. Maximum Discharge Pressure (psi). Read honest and unbiased product reviews from our users.
Excess moisture can cause damage to surfaces and equipment, and by removing the condensation the potential for damage can be reduced or eliminated. Pump includes safety switch that can be wired to . Buy Liberty Pumps LCU220S Direct. For removal of condensate from air conditioners, suitable for high efficiency, gas furnace condensation, and condensing boilers.
Features: Order Info: Downloads.