The sludge can be disposed as regular non - PCB industrial waste. The treated transformer oil is fully restore meeting the required standards, without any detectable . A polychlorinated biphenyl ( PCB ) is an organic chlorine compound with the formula C12H10−xClx. Polychlorinated biphenyls were once widely deployed as dielectric and coolant fluids in electrical apparatus, carbonless copy paper and in heat transfer fluids. Because of their longevity, PCBs are still widely in use, even .

If the nameplate says PCBs or any of the names on the above list, then the transformer most .

However, the regulations also establish numerous exceptions and authorized activities (e.g., where non -totally enclosed activities may be conducted).

Such authorizations pertain to the use of PCBs and servicing of PCBs in various PCB. Equipment, such as transformers , capacitors, natural gas pipelines, . Non - PCB Equipment Recycling and Disposal: Transformers and other oil filled equipment that are known to be less than ppm PCB are not regulated. Your company can be confident that Solomon Corporation gives prompt service on recycling and disposal jobs, as well as . Non - PCB transformer : Any transformer containing less than ppm PCB.


PCB-Contaminated Electrical Equipment: Any electrical equipment, including transformers, that contain ppm or greater PCB, but less than 5ppm PCB. PCB Transformer: Any transformer that contains 5ppm PCB or greater. PCB applications are commonly categorised as either open or closed applications as follows: Open applications: use as heat exchange fluids, hydraulic oils, lubricating oils and as additives in paints, plastics, solvents, adhesives and cements. Closed applications: use as insulating fluid in electrical transformers , capacitors, . Arizona Waste Oil purchases all transformer oil.


Nonrestricted Access Areas - Any area other than restricted access, outdoor electrical substations, and other restricted access locations. A visual inspection of each PCB. March, April through June, July through. September, and October through December, as long as there is a . In the servicing or maintenance of transformers , the dielectric fluid may be removed from the unit and filtered to remove moisture or particulate matter and returned to the same unit. If any unit requires topping up after servicing or during regular maintenance, a non PCB fluid must be used.


ABB offers turnkey replacement programs for PCB -filled transformers and capacitors that help customers translate the . Electrical equipment manufactured in Australia since then is unlikely to contain PCBs. EPS processes this equipment through an EPA . In particular it deals with the question of the reclassification of equipment as non - PCB equipment (retro-filling), thus . Mechanical rooms and electrical vaults at the University that contain older oil- filled transformers with PCB -contaminated oil must be identified and labeled. These locations are typically referred to as Non -Restricted Access Areas. Inspections of these locations are conducted regularly to .